Riteshkumar Bhojani1, Jens Kowalsky1, Josef Lutz1, Dustin Kendig2, Roman Baburske3, Hans-Joachim Schulze3, Franz-Josef Niedernostheide3 Email: riteshkumar.bhojani@etit.tu-chemnitz.de 1Chair of Power Electronics and EMC, Technische Universität Chemnitz, Chemnitz, Germany 2Microsanj, Santa Clara, USA 3Infineon Technologies AG, Neubiberg, Germany 摘要:在本文中,我们首次通过实验测量了igbt中重复短路(SC)事件下的current filaments现象。

Riteshkumar Bhojani1, Jens Kowalsky1, Josef Lutz1, Dustin Kendig2, Roman Baburske3, Hans-Joachim Schulze3, Franz-Josef Niedernostheide3

Email: riteshkumar.bhojani@etit.tu-chemnitz.de

1Chair of Power Electronics and EMC, Technische Universität Chemnitz, Chemnitz, Germany

2Microsanj, Santa Clara, USA

3Infineon Technologies AG, Neubiberg, Germany

 

摘要:在本文中,我们首次通过实验测量了igbt中重复短路(SC)事件下的current filaments现象。这些current filaments现象是通过反射率热成像系统 (TRM)发现的。对两种不同焊接方式的15A-1200V IGBT芯片进行了破坏电流的测定。重复的 SC 事件与 TRM 测量相结合,表明在不同 VCE 下存在大范围的非破坏性current filaments现象。在支持基于多单元 IGBT 结构的 TCAD 器件模拟中,观察到短路条件下类似的现象形成。他们具有与 TRM 测量的当前current filaments现象相似的尺寸。

关键词—IGBT,短路,电流丝,反射率热成像系统

Ⅰ 

INTRODUCTION

In previous works, several authors have shown short-circuit destruction limits and the improvement potential of the SC- SOA for IGBTs of different voltage classes with a minimum current destruction limit at about 50 % of the rated voltage [1- 4]. These observations were linked to the effect of current crowding at the collector side of the IGBT. Moreover, different failure modes like failure during the SC pulse and during SC turn-off were also related with the current crowding effect in IGBTs. Up to now, direct experimental evidence for the appearance of the current filaments in IGBTs during short- circuit is missing.

In this work, we investigated the behavior of the current filaments using CCD-based thermo-reflectance microscopy [5]. Under different voltage and current conditions, thermo-reflectance measurements were performed to observe the change in temperature on the top of the IGBT metallization.

Ⅱ 

THERMO-REFLECTANCE MICROSCOPY

 

In general, the complex refractive index of a material changes with temperature, and the thermo-reflectance coefficient Cth simply represents the linear change in optical reflectance of a surface due to a change in temperature (ΔT) [5]:

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Here, Cth is the thermo-reflectance coefficient, R is the reflective intensity in (J/m2), T is the temperature in (K) and    λ is the wavelength in (m).

The stroboscopic imaging was used to create time-resolved image data with temporal resolution down to 50 ns. The device is turned ON for a certain period of time at a certain duty cycle, and the CCD exposure time is also set by the user as shown in Fig. 1(a). Nearly all the light reaching the CCD will come from the LED pulses which are offset by a specific time delay relative to the device excitation, and a CCD image is generated as the sum of the LED pulses inside a single CCD exposure window. The timing diagram in Fig. 1(a) shows how the time-resolved image data is collected by pulsing the device excitation and LED probe light with a controllable relative time delay.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 1(a) Timing diagram showing how the t = 0 data point is collected (b) Timing diagram showing how the t > 0 data point is collected for heated device (c) Acquired temperature data points with respect to time.

Fig. 1(b) and (c) show how the temperature data points were acquired by shifting the time delay after each cycle to achieve time resolution, limited only by how tightly the pulse of the LED probe light was set. To create a two-dimensional transient thermo-reflectance image, a reference CCD image with LED pulse delay t = 0 was collected, followed by recording a CCD image at t > 0. Then, a sub-pixel image registration algorithm was applied to a subset of the CCD images to align the t > 0 image to the reference. After this, the registered t > 0 images were subtracted from the t = 0 reference image. This process with recording pairs of t = 0,      t > 0 images was continued as a running average to suppress noise to an acceptable level. In this way, the software automatically stepped through user-designated time delays and averaging times to collect a full time-domain image set, from the moment the device was turned on, to the time period after the device switched off and was cooling down.

Ⅲ 

SC THEORY AND FILAMENT BEHAVIOR

 

A.Simulation results of current filaments during SC

Electro-thermal device simulations were performed to estimate the surface temperature during the SC pulse when current filaments are present in the chip. Fig. 2 shows the transients of the maximum and the average current density together with the course of the maximum temperature under SC conditions for a DC-link voltage VDC = 500 V, a collector current IC = 240 A, corresponding to a gate-emitter voltage VGE = 30 V at an initial temperature Tint = 300 K for a multi- cell IGBT structure with a simplified front side structure [4]. The thermal resistance of 3.2 K/W was set at the collector contact and self-heating was considered for SC simulations.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 2. Transients of the maximum and the average current density and the transient of the maximum temperature from electro-thermal SC simulation at VDC = 500 V, IC = 240 A, Tint = 300 K.

A small window at n–base/n-field-stop junction (Fig. 3) was selected to extract the average and maximum current densities from the device. At 2.5 µs, the two current density transients start to split. At 4 µs, multiple filaments are present in the device (Fig. 3). The typical width of the filament at the emitter-side metallization was between 80 to 120 µm.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 3. Current density distribution at 4 µs in IGBT with ref. to Fig. 2.

Fig. 4 shows the surface temperature profile with respect  to a horizontal cut C1 in Fig. 3 on top of the Al metallization. At the filament positions, where the simulated temperature close to the collector is about 600 K at 4 µs, the surface temperature shows an increase by 2 to 5 K, which can be resolved using TRM.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 4. Surface temperature profile on top of the Al metallization at different time points from Fig. 2.

B.Low Inductive Short-circuit Setup

Fig. 5(left) displays the SC-setup combined with thermo- reflectance microscopy setup. Fig. 5(right) shows a close view of a SC-setup including capacitor bank, measuring probes, TRM lens and a Device Under Test (DUT). The DUT is soldered on a Direct Copper Bonding (DCB) substrate.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 5. A SC-setup with TRM camera setup (left) and an experimental setup of TRM lens with a low inductive SC-setup (right).

A very low inductive (Lpar ≤ 60 nH) short-circuit setup was designed to investigate  the current destruction limit for the   15 A-1200 V IGBTs. The short-circuit destruction limit was measured for two differently wire-bonded IGBT chips shown in Fig. 6. The gate resistors for turn-on and turn-off were set to RG = 220 Ω during all measurements.

The results shown in Fig. 6 indicate that the critical short- circuit current is independent of the number of bond wires on the top of aluminum metallization, allowing us to use chips with only one bond wire for TRM. The temperature on the top surface of the IGBT chip was continuously monitored using a “Microsanj NT210 transient thermo-reflectance camera” by performing repetitive non-destructive SC events. Fig. 7 shows a SC type-1 waveform at VDC = 400 V and VGE = 30 V. An estimated average temperature swing ΔTSC of the chip during this given pulse can be about 67 K using the whole chip volume given by Equation 2 in [6].

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 6. Destruction limit of 1.2 kV IGBTs for two differently wire-bonded chips at T = 300 K, Lpar ≤ 60 nH, RG = 220 Ω (red and black points) and SC measurement conditions at which non-destructive filaments were investigated by means of TRM (scattered points).

使用反射率热成像系统观察IGBTs中的Current Filaments现象

where c is the specific heat capacity of silicon, r is the density of silicon, d and A are thickness and area of the chip.

With TRM, the uncovered Al surface was monitored for different VDC by performing repetitive SC events close below the destruction limit. The measurements were performed for gate voltages close to the chip destruction as well as for reduced gate voltages. The SC pulse length was set to 4 µs. The time between each consecutive  SC  pulse  was  set  to 200 ms which was sufficient to cool down the IGBT top aluminum metallization. The scattered points in Fig. 6 refer to measurement conditions of the IGBT chips at which TRM measurements were performed with different VDC, VGE and IC.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig.  7.  Transients  of the VCE(t),  VGE(t) and  IC(t) for   a  SC  type-1  event  at  VCE = 400 V, VGE = 30 V, T = 300 K, Lpar = 60 nH and RG = 220 Ω.

C.Destructive and non-destructive filaments

Fig. 8 schematically illustrates the areas in the  IC-VCE phase space in which either no filaments or non-destructive filaments were observed by TRM. The red-solid line marks  the dependency of the destruction current on VCE under SC conditions with the minimum critical SC current lying at about VCE,rated/2 for the investigated 1200 V IGBTs. The green line explicates the current level above which filament appears. The hatched area in Fig. 8 between the red-solid and the green- dashed line covers the non-destructive visible filaments, especially at a low VCE range from 300 V to 600 V. The filament pattern becomes finer from VCE of 300 V to 600 V. For VCE > 600 V, the filament behavior needs to be inquire further. In the area below the green-dashed line, current crowding did not appear and the current flowed uniformly in the IGBT during SC event. The black line indicates the IC-VCE characteristic for VGE ≤ 15 V. For the safe operation of the IGBT device during SC case, it is essential to evaluate this green-dashed boundary line. Therefore, the focus of the TRM was different gate voltages at which the uniform current distribution transformed into a distribution with current filaments, indicated by green-dashed line in Fig. 8, especially at low VCE voltages.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 8. Schematic illustration of the border lines for destructive and non- destructive filament areas in IC-VCE phase space.

Ⅳ 

TRM RESULTS AND DISCUSSION

Fig. 9 displays the TRM images at different DC-link voltages and different gate voltages. At VDC = 400 V and VGE of 30 V (Fig. 9a), after integration over several thousand SC pulses, temperature peaks are visible  for  the  IGBT  chip  with one emitter bond wire. The TRM images show the temperature difference (ΔT), between t = 0 and t > 0 images, and not the actual temperature. The blue color indicates the coldest region on the IGBT chip. The red spots show high temperature areas indicating filaments in the IGBT. They have similar dimensions as the filaments  found  in  simulation  (Fig. 3). The diameter of the current filaments ranges from minimum 40 µm to maximum 140 µm. Their distance varies from 50 µm to 200 µm. The different maximum temperatures at the position of the current filaments indicate that the filaments were carrying different currents. For certain conditions also clustering of filaments was observed.

For VDC/VGE = 300 V/36 V, 400 V/23 V and 500 V/17.5 V (Fig. 9c-e) again the filaments appeared. For VDC = 400 V and 500 V, the gate voltage is 12 V and 7 V lower that the critical gate voltage at which destruction occurs, indicating a wide gate voltage and collector current interval at which non-destructive filaments may appear. The filament pattern was almost regular for VDC = 400 V (Fig. 9d). However, there is a gradient of the maximum filament temperature from the left to the right edge of the TRM image.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 9. Surface temperature observation after series of SC pulses using TRM camera at different  VDC  and VGE. (Scale: temperature difference to coldest point     (x: 3.7 mm, y: 2.8 mm))

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 10. 3D-TRM image after SC events at VDC = 400 V (ref. to Fig. 9(a), Scale: 0.1× (X, Y)).

使用反射率热成像系统观察IGBTs中的Current Filaments现象

Fig. 11. Measured average surface temperature profile on top of the Al metallization from three different regions with respect to time.

Fig. 10 shows the 3D-TRM picture of the temperature profile with respect to Fig. 9(a) at VDC =400 V. Fig. 11 shows the measured average surface temperature profile on top of aluminum metallization from three different regions with respect to time after repetitive SC events. These three different regions R1, R2 and R3 were selected from Fig. 9(b) after several repetition of the short-circuit events at VDC = 600 V and VGE = 21 V. Since the heat inside the chip takes some time to reach the top metallization, one can initially see a very small increase in temperature. After 50 µs, the temperature on the chip surface reaches the maximum value and remains the same for another 50 µs. From 100 µs, the temperature of the aluminum metallization starts to decay. Several 10 milli- seconds after the SC pulse, the Al surface metallization reaches its initial temperature.

Ⅴ 

CONCLUSION

 

Current filaments were observed in IGBTs during repetitive SC events using thermo reflectance microscopy. The diameters of the filaments varied between 40 µm and 140 µm and were comparable to the width of  filaments  (80 µm  to 120 µm) found in supporting TCAD device simulations. The filaments were more pronounced for low DC-link voltages (300 V to 600 V), while at higher DC-link voltages, the filament pattern became finer and transformed to a homogeneous distribution. The filaments were also found at gate voltages lower than the critical gate voltages. The measured results indicate that there is a wide current range where the non-destructive filaments can appear inside the IGBT device during repetitive SC events. In all measurements, irregular patterns of filaments were observed. However, the filaments showed characteristic dimensions and were spaced apart from each other by characteristic distances.

使用反射率热成像系统观察IGBTs中的Current Filaments现象

ACKNOWLEDGEMENT

The authors would like to thank Madhu Lakshman Mysore for his help during the measurement and also to Manuela Schulze for critically reading the manuscript.

 

 

免责声明:文章内容不代表本站立场,本站不对其内容的真实性、完整性、准确性给予任何担保、暗示和承诺,仅供读者参考,文章版权归原作者所有。如本文内容影响到您的合法权益(内容、图片等),请及时联系本站,我们会及时删除处理。

作者: suifengmianlai

为您推荐

生产制造 | 数控仿真保证“安全” 之 NCSIMUL四轴机床搭建

NCSIMUL 通过上一期对三轴机床搭建的讲解和演示,想必大家已经能够搭建自己专属的三轴机床。

质量管理 | 海克斯康 Q-DAS®与SAP QM的交互应用方案

SAP(System Applications and Product) 软件在企业的部署着眼于中央业务流程的优化。

新能源汽车供应链强力转型,数字化供应链系统订单管理数字化助力企业降本增效

当前,全球新能源汽车产业发展驶入快车道,新产品新技术加快研发运用,技术创新带动产业持续升级。

进度猫甘特图:项目管理中的任务分解工具

项目管理中是将大的项目目标划分为各个小阶段任务,WBS就是化繁为简,将负责非项目拆分为简单的任务,它可让事情依照一定规则或关系,通过一层一层来分解,这样要做的任务可以变为小目标。

查看流程审批历史记录解决方案

作者:黄鹏 审校:李达 适用版本:TC11 用户可以在TC中看到整个流程的历史记录,包括驳回,审批,编制的操作,这样可以方便我们查看哪些人参与了这个流程。

发表回复

您的电子邮箱地址不会被公开。 必填项已用*标注

返回顶部